CBB61 Ceiling Fan Capacitor

$8.99

Description

When a ceiling fan suddenly only runs on one speed, crawls along on high, or hums without turning until you give the blades a push, the capacitor tucked inside the switch housing is the first part to suspect, and it’s usually the cheapest fix you’ll ever make on a fan. This CBB61 is a three section, five wire capacitor rated at 4.5 µF, 6 µF, and 5 µF, built for 250V AC at 50/60Hz with a ±5% tolerance and a maximum operating temperature of 70°C, which covers the heat that builds up inside a closed switch housing under a running motor. Capacitors in this style are used across a huge range of three speed pull chain fans, including many Hampton Bay models, but CBB61 is a type of capacitor rather than a single part number, so the values printed on your old one are what decide whether this unit fits. The sections below cover how to confirm the capacitor is really your problem, how to read the old label, how to test it, and how to swap it in without losing track of the wiring. If you’re working through a list of possible causes, our ceiling fan troubleshooting FAQ is a good companion to this page.

A Fan Stuck on One Speed or Humming Without Spinning

Capacitor failure has a recognizable pattern once you know what to look for. On a three speed fan, each speed setting sends power through a different section or combination of sections in the capacitor, so when one section weakens or opens up, the speed that depends on it either disappears or drops so low it feels like nothing changed. The classic complaint is a fan where low and medium feel almost the same, or where high is noticeably slower than it used to be, or where the speeds come out in the wrong order so that the second pull on the chain is actually the fastest. The other common symptom is a motor that hums and sits still when you turn it on, then starts spinning normally if you nudge a blade by hand, which tells you the motor itself has power but isn’t getting the phase shift it needs to start on its own. Capacitors wear out gradually from heat and age, so these symptoms often creep in over months, and it’s common for an owner to realize the fan has been underperforming for a whole summer before it finally gets bad enough to notice. If what you’re hearing is grinding, scraping, or a rhythmic tick rather than a hum, the capacitor probably isn’t the cause, and our guide to Hampton Bay ceiling fan motor troubleshooting covers bearings, loose parts, and other mechanical noises in detail.

Ruling Out the Pull Chain Switch Before Buying a Capacitor

The speed switch and the capacitor sit right next to each other and work together, which makes them easy to confuse, so it’s worth spending two minutes ruling out the switch first. A failing pull chain switch tends to produce dead positions, where one pull does nothing at all and the next pull suddenly works, or it stops clicking crisply and the chain spins or feels mushy. Sometimes the chain breaks off inside the housing entirely, or the fan gets stuck running on one speed because the switch mechanism has jammed rather than because a capacitor section failed. A weak capacitor, by contrast, usually still lets every chain position do something, just not the right thing, with speeds that are too slow or blurred together. If you pull the chain slowly and listen, a healthy switch gives you a distinct click at every position, and if some positions produce no click or no change at all, the switch deserves the blame. The process for getting into the housing and replacing a switch is very similar to a capacitor swap, and our walkthrough for when a Hampton Bay pull chain breaks shows the layout you’ll find once the cover comes off. Since both parts live in the same space and both age from the same heat, plenty of people replace the switch and capacitor together while they have everything open.

Remote Controlled Fans Usually Hide the Problem in the Receiver

If your fan runs on a handheld remote or a wall control rather than a pull chain, the speed problem may not involve this capacitor at all. On most remote setups, a receiver module mounted up in the canopy handles speed control using its own internal components, and when that receiver starts failing you get the same sort of lost speeds, weak high setting, or motor hum that a bad fan capacitor produces. Some fans still have a capacitor in the switch housing even with a remote installed, particularly when a remote kit was added to a fan that originally shipped with a pull chain, so the only way to know for sure is to look. Start by checking the batteries and re-pairing the remote, then look at whether the problem affects all speeds or just one, and whether the light is behaving normally. Our guide to troubleshooting ceiling fan remotes covers the receiver side step by step, and if your fan is doing stranger things like switching on by itself, the article on a Hampton Bay fan turning on by itself at night points straight at receiver and interference issues. Replacing a capacitor on a fan whose receiver is the real culprit won’t hurt anything, but it also won’t fix it.

Reading the Label on Your Old CBB61 Before You Order

Every CBB61 capacitor has its values printed right on the case, and those numbers are the only reliable way to confirm a match. You’re looking for the capacitance of each section, written in microfarads using µF, uF, or MFD, along with the voltage rating and a small diagram showing which wires connect to which section. This unit is marked 4.5 µF, 6 µF, and 5 µF, which means your old capacitor should show those same three values. The voltage rating on the replacement needs to be equal to or higher than the original, and since most fan capacitors are rated at 250V, this one covers the typical case. Wire count matters too, because a five wire capacitor is laid out differently from a four wire version with the same capacitance values, and trying to adapt one to the other means guessing at which leads are common. Pay particular attention to the order of the sections on the diagram. Two capacitors can carry the exact same three values and still assign them to different wire pairs, which is why the wiring diagram on the label matters as much as the numbers themselves. Finally, check the physical size. Switch housings on some compact fans leave very little room, and a capacitor that’s electrically perfect but slightly too large can make it impossible to close the cover. If your old label is burnt, melted, or simply unreadable, the parts list in your fan’s manual often names the capacitor values, and our Hampton Bay ceiling fan manuals library is the quickest place to look them up by model.

Why Close Enough Values Scramble Your Fan Speeds

It’s tempting to grab whatever capacitor looks similar at a hardware store, but the three sections aren’t interchangeable approximations, because each value sets how fast the motor spins on a particular chain position. Swap in a capacitor where the sections are a little different or wired in a different order and you’ll often end up with speeds that come out of sequence, a low setting that’s too fast to sleep under, or a high setting that never reaches full speed. Go too high on capacitance for a given section and the motor can run hotter than it was designed to, which shortens its life and can eventually damage the windings. The ±5% tolerance on this capacitor is simply the normal manufacturing range around each marked value, so a 6 µF section measuring slightly above or below 6 on a meter is perfectly fine. The goal is to match what the fan was built with, not to improve on it. If you can’t find an exact match for your old capacitor, it’s worth reaching out through the channels in our guide to speaking with Hampton Bay customer service, since they can sometimes identify the correct part from your model number, and a fan still covered by a registered Hampton Bay warranty may qualify for a free replacement.

Testing the Old Capacitor With a Multimeter

You don’t strictly need to test the old capacitor before replacing it, since at this price a swap is often the fastest diagnosis, but a quick test confirms you’re chasing the right part. You’ll need a multimeter with a capacitance setting, usually marked with the capacitor symbol or labelled F. With power off at the breaker and the capacitor disconnected from the fan wiring, briefly short the leads of each section together with an insulated screwdriver or a resistor to make sure any leftover charge is gone. Then measure each section by placing the meter probes on the two wires that the label diagram assigns to it. A healthy section reads close to its marked value, within a few percent. A section that reads far below its rating, reads zero, or shows as open is the one that’s been causing your speed problem. It’s also worth giving the old capacitor a close look while it’s in your hand. A swollen or bulging case, a cracked or melted casing, a burnt smell, or any discoloration all mean the capacitor has failed regardless of what the meter says. If every section tests perfectly and the case looks clean, the capacitor probably isn’t your problem, and you’ll want to go back and look harder at the switch, the wiring connections, or the motor itself.

Getting Into the Switch Housing and Swapping Wires One at a Time

Start by shutting off power at the breaker, not just at the wall switch, since the switch housing contains live connections whenever the circuit is energized. On most fans the capacitor lives in the switch housing directly below the motor, which is the same cup where the pull chains come out. If your fan has a light kit, you’ll usually need to remove the glass, bulbs, and light kit first, then remove the three or four screws holding the switch housing cover. Lower the cover carefully and you’ll see the capacitor, often a small black or white rectangular block, connected to the speed switch and the motor leads with wire nuts or crimp connectors. The single most useful habit during this job is to move one wire at a time. Take a clear photo of the existing connections before touching anything, then cut or disconnect one wire from the old capacitor, connect the matching wire from the new capacitor in its place, and only then move on to the next. Match wires by their position on the label diagram rather than by color alone, because different manufacturers use different wire colors for the same function. Strip about half an inch of insulation from each new lead if it isn’t pre-stripped, twist the connection firmly, and secure it with a properly sized wire nut, tugging gently on each wire afterward to make sure nothing pulls loose. Tuck the connections neatly so no bare copper can touch the metal housing, seat the capacitor where the old one sat, and reassemble in reverse order. If you’re unsure how your particular fan is wired or want to double check the switch connections, our collection of Hampton Bay wiring diagrams shows the typical layouts for pull chain fans.

If the Fan Still Won’t Run Right After the Swap

When a new capacitor doesn’t cure the symptom, the most common reason is a single wire landing on the wrong terminal, so before anything else, turn the power back off and compare your connections against the photo you took and the diagram on the new capacitor’s label. Speeds that come out in a strange order almost always point to two leads being swapped, and it’s usually a quick fix. If the wiring checks out and the fan still hums, runs weakly on every speed, or shuts off after running for a while, the motor windings or bearings may be failing, and at that point it’s worth weighing whether a repair makes sense against the age of the fan. Our motor troubleshooting and replacement guide walks through that decision, and if you’d rather have someone else handle it, the local fan repair section can help you find help in your area. While you have the fan apart, it’s a good time to inspect the rest of the hardware too. Bent blade arms are a frequent cause of wobble on older fans, and we carry a replacement blade arm bracket for the Hampton Bay Glendale II along with a walkthrough on installing a ceiling fan blade bracket. If your fan hangs from a tall or sloped ceiling and sits too close to the ceiling for good airflow, a longer rod like the Steerg 36 inch downrod can help. For everything else, the full ceiling fan parts catalog and our Hampton Bay replacement parts hub cover the rest of what you might need to get the fan running like new.